0106961 发表于 2024-7-10 18:16:53

1台变频器驱动多台异步电机运行的电机参数该如何设置?

<p><span style=";font-family:宋体;font-size:14px"><span style="font-family:宋体">采用</span><span style="font-family:Calibri">VF</span><span style="font-family:宋体">控制模式,根据电机铭牌正确设置电机参数</span></span><span style=";font-family:宋体;font-size:14px"><span style="font-family:宋体">(</span></span><span style=";font-family:宋体;font-size:14px"><span style="font-family:宋体">额定频率</span><span style="font-family:Calibri">P2.02</span><span style="font-family:宋体">,额定转速</span><span style="font-family:Calibri">P2.03,</span><span style="font-family:宋体">额定电压</span><span style="font-family:Calibri">2.04</span></span><span style=";font-family:宋体;font-size:14px"><span style="font-family:宋体">)</span></span><span style=";font-family:宋体;font-size:14px"><span style="font-family:宋体">,同时根据根据</span></span><span style=";font-family:宋体;font-size:14px"><span style="font-family:宋体">多台</span></span><span style=";font-family:宋体;font-size:14px"><span style="font-family:宋体">电机功率之和设置</span><span style="font-family:Calibri">P02.01</span><span style="font-family:宋体">电机功率大小,并且将</span><span style="font-family:Calibri">P02.05</span><span style="font-family:宋体">额定电流设置为比</span></span><span style=";font-family:宋体;font-size:14px"><span style="font-family:宋体">多台</span></span><span style=";font-family:宋体;font-size:14px"><span style="font-family:宋体">电机额定电流之和稍大的值</span></span></p><p><br/></p>