DA180系列400伺服同时报13-0/07-0故障问题解析
<p><span style="font-family:宋体">故障分析:</span></p><p><img src="/upload/article/20221115/1668494032473837.png" title="1668494032473837.png" alt="企业微信截图_1668494020630.png"/></p><p><br/></p><p>DA180<span style="font-family:宋体">系列</span>400w<span style="font-family:宋体">没有内置电阻,客户高速启停时容易出现</span>07-0<span style="font-family:宋体">和</span>13-0<span style="font-family:宋体">问题。</span></p><p> </p><p><span style="font-family:宋体">解决措施:</span></p><p> </p><p><span style="font-family:宋体">添加外部制动电阻,</span>p0.13<span style="font-family:宋体">设置制动电阻功率,</span>p0.14<span style="font-family:宋体">设置制动电阻阻值,</span>p4.34<span style="font-family:宋体">设置外接制动电阻。</span></p><p><img src="/upload/article/20221115/1668494067451604.png" title="1668494067451604.png" alt="企业微信截图_16684940626057.png"/></p><p> </p><p><br/></p>