huty_2022 发表于 2024-7-10 18:16:53

IVC1L-1616MAR6 2PT温度检测如和编程使用?

<p>IVC1L-1616MAR6 是一款集成2PT于本体的PLC 温度检测在AutoStation 编程使用时需要调用的特定的SD特殊元件如:&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 地址号<span style="white-space: pre;">        </span>名称<span style="white-space: pre;">        </span>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;读写属性<span style="white-space: pre;">        </span>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 备注</p><p>SD172<span style="white-space:pre">        </span>通道1的采样平均值<span style="white-space:pre">        </span>R<span style="white-space:pre">        </span>默认值:0</p><p>SD173<span style="white-space:pre">        </span>通道1的采样次数<span style="white-space:pre">        </span>RW<span style="white-space:pre">        </span>1-1000,默认值:8</p><p>SD174<span style="white-space:pre">        </span>通道2的采样平均值<span style="white-space:pre">        </span>R<span style="white-space:pre">        </span>默认值:0</p><p>SD175<span style="white-space:pre">        </span>通道2的采样次数<span style="white-space:pre">        </span>RW<span style="white-space:pre">        </span>1-1000,默认值:8</p><p>SD178<span style="white-space:pre">        </span>通道1的模式选择</p><p>(低8位)</p><p>通道2的模式选择</p><p>(高8位)<span style="white-space:pre">        </span>RW<span style="white-space:pre">        </span>0:关闭 </p><p>1:PT100摄氏度 -1500-6000</p><p>2:PT100华氏度 -2380-11120</p><p>3:Cu100摄氏度 -300-1200</p><p>4:Cu100华氏度 -220-2480</p><p>5:Cu50摄氏度 -300-1200</p><p>6:Cu50华氏度 -220-2480</p><p><br/></p>
页: [1]